Magnetic Float Indicator - MLG28

Based on a single float and magnetic flaps or float indicator. The measuring tube that carries a float is installed like an external chamber to the side of a tank.

The magnet inside the float actuates the magnetic flaps or float indicator according to change in liquid level in the measuring tube.

The float or column of yellow colour flaps indicates the liquid level in the tank which corresponds to the liquid level in the measuring tube.

Magnetic Float Indicator Principle


Features

  • Different wetted part materials are available. For example stainless Steel, PTFE and PVC.

  • Rugged construction for the roughest industrial applications. These indicators perform in high temperature, high pressure, and many other applications requiring robust and high-quality design.

  • Little or no materials required and less risk of leakage than a sight glass

  • Add-on switches for Alarms and level control

  • Add-on 4-20mA transmitter suitable for temperature up to 200°C with special heat insulated cover on the measuring tube.

  • Level gauge with 4-20mA transmitter suitable for temperature up to 200°C with special heat insulation cover on the measuring tube.

  • Level measurement for low and medium height vessel or tank.

  • Measurement unaffected by presence of mechanical agitator or color of the fluid.

  • Can be used for interface level measurement. For example oil/water and foam/liquid.

Instruments Versions

Version Flange Gasket Measuring Tube Maximum Allowable
Operating Pressure**
Maximum Fluid
Temperature
MLG28/SS SS 316L PTFE SS 316 L 40 bar 200°C
MLG28/PTFE SS 316L PTFE SS304L – with PTFE liner 40 bar 200°C
MLG28/PVC PVC PTFE PVC 6 bar 40°C

**Depending on material and flange pressure selection


Applications

Magnetic Float Indicator Picture

  • Rugged construction for the roughest industrial applications. These indicators perform in high temperature, high pressure, and many other applications requiring robust and high-quality design.

  • Level measurement for low and medium height vessel or tank.

  • Measurement unaffected by presence of mechanical agitator or color of the fluid.

  • Can be used for interface level measurement. For example oil/water and foam/liquid.


Related Indutsry

  • Chemical

  • Pulp and Paper

  • Water/Wasterwater

  • Pharmaceutical

  • Oil and Gas

  • Food and Beverages

Specifications

Technical Details
Accuracy ± 5 mm of actual level
Maximum Fluid Viscosity 5000 cP
Maximum Allowable
Operating Pressure
40 bar - depend on material, flange pressure rating
(higher pressure on request)
Measuring Range 0.3 to 6m (for SS and PTFE version)
0.3 to 3m (for PVC version)
Maximum Fluid Temperature Standard: -20°C to +200°C
Option: -20°C to +400°C
Minimum Fluid Density (Float) ≤0.55 kg/l (SS/PTFE) , ≤0.85 kg/l (PVC)
Process Connection DN15...50 PN 16/40; 1/2”...2” ANSI 150/300lbs, others on request
Float Material 316 SS, PVC, PTFE, Titanium
Gasket Material PTFE (standard), Steel*
Flange Material 316 SS, PVC
Indicator Type Bi-flap or float* indicator
Mounting Position Vertical - side/side, top/bottom and others on request
Ingress Protection (Indicator) and others on request
Ingress Protection (Indicator) IP 68 (Equivalent to NEMA 6)
Optional Features Limit switch (bi-stable switch)
Remote signal transmitter (4-20mA)
Isolation valves
Vent / drain valves
Note: Specification are subject to change without notice.

*Selection for operating temperature above 200°C


Enquiry

For all inquiries, you may contact us through Telephone, Email or Live Chat Support.

Operating Hours

Monday to Friday: 8.00am to 5.30pm

Technical Support (After Office Hours)

Tel: (65) 9876 6258

Contact Information

By Phone / FaxBy Email
Tel: (65) 6553 0366
Fax: (65) 6553 0828
info@flotech.com.sg

Flotech Approvals